Introduction
This is a simple-to-use Carbon Monoxide (CO) sensor, suitable for sensing CO concentrations in the air. The MQ-7 can detect CO-gas concentrations anywhere from 20 to 2000ppm.
Features
- High sensitivity to CH4,Natural gas
- Small sensitivity to alcohol, smoke
- Fast response
- Stable and long life
- Simple drive circuit
Specification
MQ-7 datasheet [1]
Usage
VCC - 5V GND - GND S - Analog pin0
Example code
int sensorValue; void setup() { Serial.begin(9600); // sets the serial port to 9600 } void loop() { sensorValue = analogRead(0); // read analog input pin 0 Serial.println(sensorValue, DEC); // prints the value read delay(100); // wait 100ms for next reading }
How to buy it