Difference between revisions of "Gas Sensor - MQ-2"
m (→Introduction) |
|||
(9 intermediate revisions by the same user not shown) | |||
Line 5: | Line 5: | ||
Arduino MQ-2 gas sensor module are used in gas leakage detecting equipments in family and industry, are suitable for detecting of LPG, i-butane, propane, methane ,alcohol, Hydrogen, smoke. | Arduino MQ-2 gas sensor module are used in gas leakage detecting equipments in family and industry, are suitable for detecting of LPG, i-butane, propane, methane ,alcohol, Hydrogen, smoke. | ||
− | Features: | + | Features: <br> |
Wide detecting scope<br> | Wide detecting scope<br> | ||
Fast response and High sensitivity<br> | Fast response and High sensitivity<br> | ||
Stable and long life<br> | Stable and long life<br> | ||
− | Simple drive | + | Simple drive circuit<br> |
==Specification== | ==Specification== | ||
Line 31: | Line 31: | ||
Humidity: ≤ 70% RH<br> | Humidity: ≤ 70% RH<br> | ||
− | == | + | ==Document== |
[MQ-2 datasheet] | [MQ-2 datasheet] | ||
==Usage== | ==Usage== | ||
+ | [[File:MQ-usage.jpg]] | ||
+ | |||
[[File:MO-2 2.jpg]] | [[File:MO-2 2.jpg]] | ||
+ | |||
+ | VCC - 5V | ||
+ | GND - GND | ||
+ | S - Analog pin0 | ||
==Example code== | ==Example code== |
Latest revision as of 06:45, 10 May 2012
Introduction
Arduino MQ-2 gas sensor module are used in gas leakage detecting equipments in family and industry, are suitable for detecting of LPG, i-butane, propane, methane ,alcohol, Hydrogen, smoke.
Features:
Wide detecting scope
Fast response and High sensitivity
Stable and long life
Simple drive circuit
Specification
Detection range: 300 to 10000ppmm
The characteristics gas: 1000ppmm, isobutane
Sensitivity: R in air / Rin, typical gas ≥ 5
Sensing Resistance: 1KΩ 50ppm toluene to 20KΩ in.
Response time: ≤ 10s
Recovery time: ≤ 30s
Heat resistance: 31Ω ± 3Ω
Heating current: ≤ 180mA
Heating voltage: 5.0V ± 0.2V
Heating power: ≤ 900mW
Measuring voltage: ≤ 24V
Working conditions of ambient temperature: -20 ℃ ~ +55 ℃
Humidity: ≤ 95% RH
Environmental oxygen content: 21%
Storage conditions Temperature: -20 ° C to +70 ° C
Humidity: ≤ 70% RH
Document
[MQ-2 datasheet]
Usage
VCC - 5V GND - GND S - Analog pin0
Example code
int sensorValue; void setup() { Serial.begin(9600); // sets the serial port to 9600 } void loop() { sensorValue = analogRead(0); // read analog input pin 0 Serial.println(sensorValue, DEC); // prints the value read delay(100); // wait 100ms for next reading }