Difference between revisions of "Humidity /Temperature Sensor Module HSM-20G"

From Geeetech Wiki
Jump to: navigation, search
 
(13 intermediate revisions by the same user not shown)
Line 1: Line 1:
=Humidity /Temperature Sensor Module HSM-20G=
+
==introduction==
 +
[[File:HSM-20G.jpg]]
  
The module of HSM-20G is essential for those applications where the relative humidity can be converted to standard voltage output.
+
The module of HSM-20G is essential for those applications where the relative humidity can be converted to standard voltage output.
  
=Applications=
+
==Applications==
 
*Humidifiers & dehumidifiers   
 
*Humidifiers & dehumidifiers   
 
*Air-conditioner   
 
*Air-conditioner   
Line 10: Line 11:
 
*Other applications   
 
*Other applications   
  
=Specifications=
+
==Specifications==
 
Specifications:   
 
Specifications:   
  
Line 42: Line 43:
  
 
15、Dimensions(L*W)  : 34mm*22mm*9mm
 
15、Dimensions(L*W)  : 34mm*22mm*9mm
 +
 +
==Typical Response==
 +
===Typical Response of HSM-20G at 25 ℃===
 +
 
 +
[[File:Typical Response of HSM-20G.jpg]]
 +
 +
[[File:HSM-20G1.jpg|400px]]
 +
 +
 +
===Temperature Output Signal===
 +
[[File:HSM-20G2.jpg]]
 +
 +
[[File:HSM-20G3.jpg|400px]]
 +
 +
== Recommended circuit==
 +
 +
[[File:HSM-20G4.jpg]]
 +
[[File:HSM-20G5.jpg]]

Latest revision as of 02:53, 2 May 2012

introduction

HSM-20G.jpg

The module of HSM-20G is essential for those applications where the relative humidity can be converted to standard voltage output.

Applications

  • Humidifiers & dehumidifiers
  • Air-conditioner
  • Humidity data loggers
  • Automotive climate control
  • Other applications

Specifications

Specifications:

1、Characteristics : HSM-20G

2、Input voltage range : DC 5.0±0.2V

3、Output voltage range : DC 1-3.19V

4、Measurement Accuracy : ±5% RH

5、Operating Current (Maximum) : 2mA

6、Storage RH Range : 0 to 99% RH

7、Operating RH Range : 20 to 95% (100% RH intermittent)

8、Transient Condensation : < 3%RH

9、Storage : -20℃ to 70℃

10、Operating : 0℃ to 50℃

11、Hysteresis (RH @ 25℃) : MAX 2%RH

12、Long Term Stability(typical drift per year) : ±1.5%

13、Linearity : Linearity

14、Time Response(63% step change) : 1 min

15、Dimensions(L*W) : 34mm*22mm*9mm

Typical Response

Typical Response of HSM-20G at 25 ℃

Typical Response of HSM-20G.jpg

HSM-20G1.jpg


Temperature Output Signal

HSM-20G2.jpg

HSM-20G3.jpg

Recommended circuit

HSM-20G4.jpg HSM-20G5.jpg